Event Details
- The need for protection
- An overview of power system fault analysis
- Protection fundamentals
- Relay transducers, both current and future
- System grounding principles
- Overcurrent earth fault protection
- Coordination principles
- Transformer protection
- Generator protection
- Bus protection
- Motor protection
- Line and feeder protection
- Principles of relay application
COURSE CONTENT
Need for Protection
- Selectivity, stability, sensitivity, speed, reliability, dependability, security
Fault Types & Their Effects
- Active, incipient, passive, transient, asymmetrical
- Phase & earth faults
Simple Calculation of Short Circuit Currents
- Revision of simple formulae
- Calculation of short circuit MVA & fault currents
- Worked examples
System Earthing
- Solid, impedance, touch potentials
- Effect of electric shock
- Earth leakage protection
Protection System Components Including Fuses
- History, construction & characteristics
- Energy let through & applications
Instrument Transformers
- Current transformers: construction, performance, specification, magnetization curves
- Voltage transformers: types, accuracy, connections
Circuit Breakers
- Purpose & duty, clearance times, types
Tripping Batteries
- Battery types, chargers, maintenance, D.C. circuitry
Relays
- Inverse definite minimum time (IDMT) relay
- Construction principles and setting
- Calculation of settings - practical examples
- New Era - modern numerical relays & future trends
Practical Demonstrations and Sessions
- Including simple fault calculations and relay settings
Co-Ordination by time Grading
- Problems in applying IDMT relays
Low Voltage Networks
- Air & molded circuit breakers
- Construction and installation
- Protection tripping characteristics
- Selective co-ordination (current limiting, earth leakage protection, cascading)
Principles of Unit Protection
- Differential protection - basic principles
Feeder Protection
- Cables
- Pilot wire differential
- Overhead lines
- Distance protection (basic principles, characteristics, various schemes)
Transformer Protection
- Phase shift, magnetising in-rush, inter-turn, core & tank faults
- Differential & restricted earth fault schemes
- Bucholz relay, oil & winding temperature
- Oil - testing & gas analysis
Switchgear (Busbar) Protection
- Requirements, zones, types
- Frame leakage
- Reverse blocking
- High, medium & low impedance schemes
Motor Protection
- Thermal overload, time constraints, early relays, starting & stalling conditions
- Unbalanced supply voltages, negative sequence currents, de-rating factors
- Phase faults protection
- Earth faults - core balance, residual stabilizing resistors
Generator Protection
- Stator & rotor faults
- Overload & over-voltage
- Reverse power, unbalanced loading
- Loss of excitation and synchronism
- Typical protection scheme for industrial generators
FOR WHOM:
Works, Services and Maintenance Personnel
TRAINING METHODOLOGY
The training methodology combines lectures, discussions, group exercises and illustrations. Participants will gain both theoretical and practical knowledge of the topics. The emphasis is on the practical application of the topics and as a result participant will go back to the workplace with both the ability and the confidence to apply the techniques learned to their duties.
This course is available in the following locations:
Nigeria - $5500
Rwanda - $7500
UK - $8500
USA - $8500